Analyse d'un système de toiture froide pour la réduction des charges frigorifiques et l'amélioration de l'efficacité du système de refroidissement.
Analysis of a cool roof system for reducing cooling loads and improving cooling system efficiency.
Numéro : pap. 842
Auteurs : PISELLO A. L., THIEMANN A., SANTAMOURIS M., et al.
Résumé
This paper presents the results of an experimental campaign aimed at estimating the impact of an innovative cool roof system on thermal behavior and energy performance of an air-conditioned office area located within an industrial building in Rome, Italy. An experimental monitoring has been carried out during summer 2012 to assess both indoor and outdoor thermal conditions of the building and the heat-pump cooling system consumption data have been collected during the same period, both before and after the cool roof implementation. The continuous monitoring data has been coupled with infrared thermographies and in-field albedo measurements of the roof, to assess the cool roof performance also as retrofit strategy for such low performance, weakly insulated, roof structures, typical for Italian industrial architecture. Experimental results demonstrate the cool roof capability to decrease roof peak temperature up to 18°C, to maintain more stable indoor thermal conditions within the monitored office, and to reduce important thermal bridges produced by the roof structure dissimilarity. By collecting the cooling energy data both before and after the cool roof application, comparing equivalent weather conditions, an average 38% energy saving is found, produced by the cool roof passive cooling effect and by the fact that the heat pumps’ external units are located over the same cool roof, which suction air temperatures register an average decrease up to 4°C during the working day, for the considered case study.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Analysis of a cool roof system for reducing cooling loads and improving cooling system efficiency.
- Identifiant de la fiche : 30010003
- Langues : Anglais
- Sujet : Environnement
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
-
En Allemagne, le secteur tertiaire prêt à bénéf...
- Date : 05/2003
- Langues : Français
- Source : Chaud Froid Plomb. - n. 657
Voir la fiche
-
Wind towers: old technology to solve a new prob...
- Auteurs : HARRIS D. J., WEBB R. S.
- Date : 09/1996
- Langues : Anglais
Voir la fiche
-
ANALYTICAL EVALUATION OF OUTDOOR AIRFLOW RATE V...
- Auteurs : MUMMA S. A., WONG Y. M.
- Date : 1990
- Langues : Anglais
Voir la fiche
-
FREE COOLING FOR OFFICE BUILDINGS IN SOUTH AFRICA.
- Auteurs : HERMAN A. F. E.
- Date : 23/04/1990
- Langues : Anglais
Voir la fiche
-
THERMAL BEHAVIOUR AND ENERGY PERFORMANCE OF ATR...
- Auteurs : HEJAZI-HASHEMI M. G.
- Date : 01/08/1989
- Langues : Anglais
Voir la fiche