Optimisation de la conception des serpentins à tubes en cuivre MicroGroove pour les frigorigènes inflammables.
Optimization of MicroGroove Copper Tube Coil Designs for Flammable Refrigerants.
Numéro : pap. 2532
Auteurs : COTTON N. D., RHOADS A., BORTOLETTO A., et al.
Résumé
The ultralow Global Warming Potential (GWP) of propane (R290) and isobutane (R600a) refrigerants make them highly attractive for refrigerator and freezer applications, although their flammability necessitates strict use conditions with respect to refrigerant charge. Copper tubes with smaller diameters are widely used to reduce refrigerant charge. The process of downsizing copper-tube diameters involves detailed simulations and prototype construction as well as testing and validation. A proprietary heat exchanger design and simulation software tool (Jiang et al., 2006) was used to evaluate the performance of and optimize the design of domestic refrigerator condenser coils made with 5-mm outer-diameter copper tubes. Optimization was accomplished through the use of reduced order models, meta-models and a multi-objective genetic algorithm (MOGA). Reducing refrigerant charge was the primary objective. Secondary objectives included the reduction of the total footprint and the total tube-and-fin material mass. The baseline design used 6.35-mm O.D. copper tubes with a minimum wall thickness of 0.41 mm, i.e., quarter-inch tubes with 0.016-inch wall thickness. The new designs use wavy-herringbone fins with reduced fin thicknesses as compared to the baseline design. Other variables included the horizontal and vertical spacing of the tubes; number of tubes per bank; fin density; wavy fin pattern depth; tube length; and tube circuitry. For an R600a residential application, reduced internal volume was considered to be more important than the airside pressure drop. A Pareto chart is presented of optimized values from the design space. Compared to the baseline design, the best 5-mm design reduced the internal tube volume by 41 percent, along with a 57 percent reduction in coil footprint. Additionally, test data to validate the performance of prototype coils is presented with emphasis on the design, construction and manufacture of the heat exchanger coils.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Optimization of MicroGroove Copper Tube Coil Designs for Flammable Refrigerants.
- Identifiant de la fiche : 30024599
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Hydrocarbures;
Confinement, réduction de la charge en frigorigène - Mots-clés : R600a; Isobutane; Cuivre; Tube; Conception; R290; Prototype; Propane; Optimisation; Inflammabilité; Charge en frigorigène
-
Developing low charge R290 room air conditioner...
- Auteurs : DING G., REN T., et al., WU W.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Charge minimization in a 30kW air to water heat...
- Auteurs : PALM B.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Charge equation for low charge hydrocarbon base...
- Auteurs : BEEK M. van, GORP T. van, et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
R290 leakage hazards assessment of a 1 HP split...
- Auteurs : NING Q., HE G., SUN W., FAN M., LI X., HONG Z.
- Date : 07/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 139
- Formats : PDF
Voir la fiche
-
Hydrocarbon refrigerant charge limits for quies...
- Auteurs : COLBOURNE D., SUEN K. O.
- Date : 05/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 125
- Formats : PDF
Voir la fiche