Recommandé par l'IIF / Document IIF
Couverture de la demande et économies d'énergie grâce à la combinaison d'un système frigorifique au CO2 et d'un système CVC dans les supermarchés.
Demand coverage and energy savings by combined CO2 refrigeration system and HVAC in supermarkets.
Numéro : 1146
Auteurs : D'AGARO P., LIBRALATO M., TOFFOLETTI G., CORTELLA G.
Résumé
Transcritical CO2 refrigeration systems for supermarkets are more and more integrated to DHW production, space cooling & heating. In CO2 integrated solutions, the thermal loads of supermarket buildings are fully covered by the refrigeration system, but advantages in terms of total investment and running costs need to be carefully estimated. They are strongly dependent on several factors among which the quality of the building envelope, the climate, the ratio between HVAC demand and the refrigeration load. A model based on TRNSYS and in-house types, validated with field data from a fully instrumented plant in a supermarket located in Northern Italy, is used to investigate the integration as a function of the thermal loads. The size of the refrigeration unit is kept constant, four different sales area and six climate zones are considered. The full coverage of space cooling by the CRU is reached on the whole Italian territory, whereas the coverage of DHW production and space heating is guaranteed up to 90% and 83% respectively in the worst case and up to 99.3% and 100% in the most favourable case.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Demand coverage and energy savings by combined CO2 refrigeration system and HVAC in supermarkets.
- Identifiant de la fiche : 30029506
- Langues : Anglais
- Sujet : Technologie
- Source : 7th IIR International Conference on Sustainability and the Cold Chain Online. Proceedings: April 11-13 2022
- Date d'édition : 11/04/2022
- DOI : http://dx.doi.org/10.18462/iir.iccc2022.1146
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (49)
Voir le compte rendu de la conférence
-
Field tests, model validation and performance o...
- Auteurs : D'AGARO P., COPPOLA M. A., CORTELLA G.
- Date : 04/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 100
- Formats : PDF
Voir la fiche
-
Heat recovery impact on eco-efficiency of retai...
- Auteurs : RACHED W., WISNIK P., BERNARDI J. de
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Supermarket case study: analysis of refrigerati...
- Auteurs : THANASOULAS S., SAWALHA S., ARIAS J.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Monitoring of a CO2 commercial refrigeration sy...
- Auteurs : DUGARIA S., AZZOLIN M., CALABRESE L., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Influence of cooling load profile on the predic...
- Auteurs : D'AGARO P., LIBRALATO M., TOFFOLETTI G., CORTELLA G.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche