Analyse et comparaison des différents déphaseurs pour un cryorefroidisseur Stirling à tube à pulsation.
Analysis and comparison of different phase shifters for Stirling pulse tube cryocooler.
Auteurs : LEI T., PFOTENHAUER J. M., ZHOU W.
Type d'article : Article
Résumé
Investigations of phase shifters and power recovery mechanisms are of sustainable interest for developing Stirling pulse tube cryocoolers (SPTC) with higher power density, more compact design and higher efficiency. This paper investigates the phase shifting capacity and the applications of four different phase shifters, including conventional inertance tube, gas-liquid and spring-oscillator phase shifters, as well as a power recovery displacer. Distributed models based on the electro-acoustic analogy are developed to estimate the phase shifting capacity and the acoustic power dissipation of the three phase shifters without power recovery. The results show that both gas-liquid and spring-oscillator phase shifters have the distinctive capacity of phase shifting with a significant reduction in the inertial component length. Furthermore, full distributed models of SPTCs connected with different phase shifters are developed. The cooling performance of SPTCs using all four phase shifters are presented and typical phase relations are analyzed. The comparison reveals that the power recovery displacer with a more complicated configuration provides the highest efficiency. The gas-liquid and spring-oscillator phase shifters show equivalent efficiency compared with the inertance tube phase shifter. Approximately 10–20% of the acoustic power is dissipated by the phase shifters without power recovery, while 15–20% of the acoustic power can be recovered by the power recovery displacer, leading to a maximum coefficient of performance
(COP) above 0.14 at 80 K. A merit analysis is also done by presenting the pros and cons of different phase shifters.
Détails
- Titre original : Analysis and comparison of different phase shifters for Stirling pulse tube cryocooler.
- Identifiant de la fiche : 30020881
- Langues : Anglais
- Source : Cryogenics - vol. 80
- Date d'édition : 09/2016
- DOI : http://dx.doi.org/10.1016/j.cryogenics.2016.09.007
Liens
Voir d'autres articles du même numéro (31)
Voir la source
Indexation
-
Etude paramétrique comparée des performances de...
- Auteurs : NIKA P.
- Date : 02/1999
- Langues : Français
- Source : Int. J. therm. Sci. - Rev. gén. Therm. - vol. 38 - n. 2
Voir la fiche
-
Linear adjustable inertance tubes for pulse tub...
- Auteurs : ZHOU W., PFOTENHAUER J. M., NELLIS G. F.
- Date : 02/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 86
- Formats : PDF
Voir la fiche
-
Theoretical and experimental investigations on ...
- Auteurs : TAN J., DANG H.
- Date : 06/01/2017
- Langues : Anglais
- Source : Cryogenics - vol. 82
Voir la fiche
-
Effect of alternate tube characteristics on hig...
- Auteurs : SAIDI M. H., SARIKHANI N., JAFARIAN A., et al.
- Date : 21/04/2008
- Langues : Anglais
- Source : Cryogenics 2008. Proceedings of the 10th IIR International Conference
- Formats : PDF
Voir la fiche
-
Analysing different types of valve controlled p...
- Auteurs : PAN H., HOFMANN A., OELLRICH L.
- Date : 22/07/2002
- Langues : Anglais
- Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
Voir la fiche