Résumé
This study investigates the performance of an integrated CO2 (R744) heat pump and chiller unit in a Norwegian hotel. The system consists of a single unit for heating, cooling and hot water with an integrated thermal storage. The thermal system of the hotel is described and data from the first year of operation are analyzed. Using the field measurements, hot water loads and COPs are calculated and averaged to 20-minute intervals. The heating and cooling capacities supplied by the R744 unit are studied on a weekly and monthly basis to evaluate the seasonal behavior of the system. The hot water storage holds an energy capacity of 350 kWh at fully charged conditions and demonstrates peak demand reductions of more than 100 kW during a 2-day period. The results show that the hot water usage accounts for 52% of the annual heat load of the hotel. Energy efficiency analysis of the integrated R744 system reveals an annual system SCOP of 2.90, and thus an untapped system potential that can be exploited by increasing the AC load delivered by the R744 unit. Other factors that greatly influence the efficiency of the system are variations in the ambient temperature and high gas cooler exit temperatures. The latter is often a result of high temperatures in the water returning from the subsystems of the hotel. This can be improved by reducing the number of starts and stops of the R744 unit and by insuring stratification in hot water tanks.
Documents disponibles
Format PDF
Pages : 59-69
Disponible
Gratuit
Détails
- Titre original : Integrated CO2 system with HVAC and hot water for hotels: Field measurements and performance evaluation.
- Identifiant de la fiche : 30027491
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 116
- Date d'édition : 08/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.03.021
Liens
Voir d'autres articles du même numéro (14)
Voir la source
Indexation
-
Innovative reheat approach of the TES system du...
- Auteurs : ELARGA H., PARDINAS A., MINETTO S., HAFNER A.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Numerical performance investigation of a CO2 he...
- Auteurs : SMITT S. M., HAFNER A.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Integrated R744 heat pump/chiller for hotel: st...
- Auteurs : SINGH S., HAFNER A., ELARGA H., SHARMA K.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Numerical simulation of an integrated CO2<...
- Auteurs : HENKE L., ELARGA H., HAFNER A.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Energy optimization for transcritical CO2 heat ...
- Auteurs : CARMO C., BLARKE M., YAZAWA K., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche