Document IIF
Revue de la méthodologie pour définir les facteurs de sécurité pour les frigorigènes inflammables A2L à retenir en fonction des normes de sécurité des produits.
Review of methodology to set safety factors for A2L flammable refrigerant being adopted by product safety standards.
Résumé
Many new lower GWP refrigerants are flammable under certain conditions. Flammability risk can be lowered by reducing the potential for forming a refrigerant/air mixture that can reach the lower flammability limit (LFL) in the event of a leak into a confined space. Product standards are setting safety factors from 4x (25% of LFL) to 1x (100% of LFL) for A2L flammable refrigerants. This large discrepancy in safety factor practices is being driven by different methodologies in understanding of refrigerant leaks from equipment. Unfortunately when a leak occurs, uniform mixing of the refrigerant with the air does not occur immediately. This can result in localized refrigerant peak concentration that exceed the LFL which requires a safety factors to be applied to account for noise factors. An additional complication is that noise factors can vary by product application. This paper will review the practices for setting the safety factors, understanding noise factors and resulting safety margins for safety factors ranging from 4x (25% of LFL) to 1x (100% of LFL).
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Review of methodology to set safety factors for A2L flammable refrigerant being adopted by product safety standards.
- Identifiant de la fiche : 30024822
- Langues : Anglais
- Sujet : Généralités
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Date d'édition : 09/2018
- DOI : http://dx.doi.org/10.18462/iir.hfo.2018.1118
Liens
- Voir aussi : Review of methodology to set safety factors for A2L flammable refrigerant being adopted by product safety standards.
Voir d'autres communications du même compte rendu (126)
Voir le compte rendu de la conférence
Indexation
-
Review of methodology to set safety factors for...
- Auteurs : KUJAK S., HANSEN B.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Risk assessment of industrial systems with A2L ...
- Auteurs : PEARSON A.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Risk assessment of industrial systems with A2L ...
- Auteurs : PEARSON A.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Evaluation of leak detectors for flammable refr...
- Auteurs : ZHENG J., ELBEL S.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
A2L refrigerants leak and ignition testing for ...
- Auteurs : WANG X.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche