Document IIF
Réfrigérateur magnétique actif rotatif à haute fréquence : résultats expérimentaux et numériques.
Experimental and numerical results of a high frequency rotating active magnetic refrigerator.
Auteurs : LOZANO J. A., ENGELBRECHT K., BAHL C. R. H., et al.
Type d'article : Article, Article de la RIF
Résumé
Experimental results for a recently developed prototype magnetic refrigeration device at the Technical University of Denmark (DTU) were obtained and compared with numerical simulation results. A continuously rotating active magnetic regenerator (AMR) using 2.8 kg packed sphere regenerators of gadolinium (Gd) was employed. With operating frequencies up to 10 Hz and volumetric flow rates up to 600 L h-1, the prototype has shown high performance and the results are consistent with predictions from numerical modelling. Magnetocaloric properties of the Gd spheres were obtained experimentally and implemented in a one-dimensional numerical AMR model that includes also the parasitic losses from the prototype. The temperature span for a thermal load of 200 W as a function of frequency was measured and modelled. Moreover, the temperature span dependence on the cooling capacity as a function of cycle frequency was determined. A detailed study of these parasitic losses was carried out experimentally and numerically.
Documents disponibles
Format PDF
Pages : 92-98
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental and numerical results of a high frequency rotating active magnetic refrigerator.
- Identifiant de la fiche : 30009885
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 37 - n. 1
- Date d'édition : 01/2014
Liens
Voir d'autres articles du même numéro (37)
Voir la source
Indexation
- Thèmes : Froid calorique (froid magnétocalorique, électrocalorique, élastocalorique et barocalorique)
- Mots-clés : Réfrigerateur magnétique; Froid magnétocalorique; AMR; Puissance thermique; Prototype; Propriété magnétique; Modélisation; Magnétisme; Haute fréquence; Gadolinium; Experimentation; Effet magnétocalorique
-
Experimental and numerical results of a high fr...
- Auteurs : LOZANO J. A., ENGELBRECHT K., BAHL C. R. H., et al.
- Date : 17/09/2012
- Langues : Anglais
- Source : 5th International Conference on Magnetic Refrigeration at Room Temperature (Thermag V). Proceedings: Grenoble, France, September 17-20, 2012.
- Formats : PDF
Voir la fiche
-
Corrosion tests of gadolinium in various heat c...
- Auteurs : ZAMNI L., MAUDNI EL ALAMI S. el, BALLI M., et al.
- Date : 17/09/2012
- Langues : Anglais
- Source : 5th International Conference on Magnetic Refrigeration at Room Temperature (Thermag V). Proceedings: Grenoble, France, September 17-20, 2012.
- Formats : PDF
Voir la fiche
-
Thermal investigations of an experimental activ...
- Auteurs : CHIBA Y., SMAÏLI A., MAHMED C., et al.
- Date : 01/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 37 - n. 1
- Formats : PDF
Voir la fiche
-
Numerical and experimental studies on an active...
- Auteurs : CHIBA Y., SMAÏLI A., MAHMED C., et al.
- Date : 17/09/2012
- Langues : Anglais
- Source : 5th International Conference on Magnetic Refrigeration at Room Temperature (Thermag V). Proceedings: Grenoble, France, September 17-20, 2012.
- Formats : PDF
Voir la fiche
-
Concentric Halbach cylinder magnetic refrigerat...
- Auteurs : TURA A., ROWE A.
- Date : 01/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 37 - n. 1
- Formats : PDF