Réfrigérateur à dilution sèche avec une forte puissance frigorifique.
Dry dilution refrigerator with high cooling power.
Auteurs : UHLIG K.
Résumé
The author presents the construction concept and cooling capacity measurements of a 3,4 He dilution refrigerator, which was pre-cooled by a commercial pulse tube refrigerator. No cryogens are needed for the operation of this type of cryostat. The condensation of the helium mash was done in an integrated Joule-Thomson circuit, which was part of the dilution unit. The composition of the dilution unit was standard, but its components (still, heat exchangers, mixing chamber) were designed for high 3He flow. For thermometry, calibrated RuO chip resistance thermometers were available. In order to condense the mixture before an experiment, the fridge was operated like a Joule-Thomson liquefier with a relatively high inlet pressure (4 bars), where the liquid fraction of the circulating 3,4He mixture was accumulated in the dilution unit. The condensation took about 2 hours, and after 2 more hours of running, the temperature of the mixing chamber approached its minimum temperature of 10 mK. The maximum flow rate of the fridge was 1 mmol/s, and the refrigeration capacity of the mixing chamber was 700 microW at 100 mK. High cooling capacity, ease of operation and reliability distinguish this type of milli-Kelvin cooler.
Détails
- Titre original : Dry dilution refrigerator with high cooling power.
- Identifiant de la fiche : 2008-1435
- Langues : Anglais
- Date d'édition : 16/07/2007
- Source : Source : Adv. cryog. Eng., Trans. CEC/AIP Conf. Proc./Proc. CEC, Chattanooga, Tennessee
vol. 53; CP985; 1287-1291; fig.; 6 ref.
-
Single cycle dilution cryostat for a long-term ...
- Auteurs : AMAMCHYAN R. G., BELENSKIJ M., FAVORSKAYA S.
- Date : 26/04/1994
- Langues : Anglais
- Source : Cryogenics '94. The third international conference.
Voir la fiche
-
Matter and methods at low temperatures.
- Auteurs : POBELL F.
- Date : 1996
- Langues : Anglais
Voir la fiche
-
The Archeops cryostat: a dilution refrigerator ...
- Auteurs : MADET K., BENOIT A., GAUTIER B.
- Date : 22/07/2002
- Langues : Anglais
- Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
Voir la fiche
-
A closed cycle 3He-4He dilution refrigerator in...
- Auteurs : MARTIN F., VERMEULEN G., CAMUS P., et al.
- Date : 09/2010
- Langues : Anglais
- Source : 2009 Space Cryogenics Workshop, Arcadia, USA, June 23-25.
Voir la fiche
-
Application of cryocooler in the ultra-low temp...
- Auteurs : ZHAO Z., JIRMANUS M. N., BOBB L., et al.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche