IIR document
Potential of energy saving by performance inspections, report from the evaluation of 170 detailed field inspections with the "internal method".
Author(s) : BERGLÖF K., PRAKASH J.
Summary
The paper introduces two methods, the "internal" and "external" for performance inspections on refrigeration, air-conditioning and heat pump systems. It reports results from 164 performance analyses done with the "internal" method. The data has been entered into a database and the deviations from nominal data have been evaluated as well as the type of faults. In total 87% of the systems had one or more faults documented. The average deviation from nominal capacity is -8.6% and the deviation in COP is -9.7%. The most common problems are wrong charge and problems with expansion valves. The internal method is increasingly in use for maintenance, inspections and integrated in building management systems for continuous monitoring. It has proved to identify a large number of faults. It offers a possibility for significantly improved "performance inspections" to satisfy the intentions of article 9 in the Energy performance in buildings Directive.
Available documents
Format PDF
Pages: 2006-5
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Potential of energy saving by performance inspections, report from the evaluation of 170 detailed field inspections with the "internal method".
- Record ID : 2007-1244
- Languages: English
- Source: Compressors 2006: 6th International Conference on Compressors and Coolants
- Publication date: 2006/09/27
Links
See other articles from the proceedings (48)
See the conference proceedings
Indexing
-
Themes:
Refrigerating equipment: general information;
Heat pumps techniques;
Thermodynamics and changes of state;
Other air-conditioning equipment - Keywords: Refrigerating system; Measurement; Temperature; Statistics; Process; Heat pump; Performance; Pressure; Case study; Thermodynamic cycle; Air conditioning
-
Thermodynamic limitations and opportunities for...
- Author(s) : DANFOSS
- Date : 2010/10
- Languages : English
- Source: Rev. Danfoss
View record
-
Corelatia intre ireversibilitatea externa si ce...
- Author(s) : VASILESCU E. E., RADCENCO V., IONITA C., et al.
- Date : 2001/11/28
- Languages : Romanian
- Source: Eficienta, confort, conservarea energiei si protectia mediului. Volumul 1. Termodinamica si transfer de caldura. Conferinta a VIII-a, cu participare internationala.
View record
-
Performance evaluation and improvement of refri...
- Author(s) : INO N.
- Date : 2006/05/21
- Languages : English
- Source: ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
View record
-
Wärmepumpen mit maximaler Arbeitszahl.
- Author(s) : LÖFFLER M.
- Date : 2006/12
- Languages : German
- Source: KI Luft Kältetech. - vol. 42 - n. 12
View record
-
A novel graphic representation of the work loss...
- Author(s) : YAMADA H., SAIKAWA M.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record