Document IIF
Optimisation et étude expérimentale sur un système à pompe à chaleur au CO2 transcritique.
Optimization and experimental study on a transcritical CO2 heat pump system.
Auteurs : YANG J. L., MA Y. T., LI M. X., et al.
Résumé
The major object function is brought forward to analyse the structure sensitivity for the CO2 heat exchangers. The major computation results based on the system show that the small diameter tube and long tube length should be selected in the CO2 transcritical cycle. And the simulation results of the new major system indicate that the COP and the cooling capacity increased on average 15 and 18%, respectively. Based on the optimization results and some existing problems in the primary system, the new heat exchangers and some related components are designed and manufactured in order to achieve rational structure and high efficiency operation, and then the new CO2 transcritical water-to-water heat pump system is set up. The experimental results show that the COP and the cooling capacity of the new system increased on average 30% or so, and the optimization object was achieved.
Documents disponibles
Format PDF
Pages : ICR07-E2-255
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Optimization and experimental study on a transcritical CO2 heat pump system.
- Identifiant de la fiche : 2008-0051
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
Performance optimization of a transcritical CO2...
- Auteurs : RULLIERE R., COLASSON S., HABERSCHILL P.
- Date : 23/06/2009
- Langues : Anglais
- Source : 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Exergy assessment of an optimized capillary tub...
- Auteurs : AGRAWAL N., BHATTACHARYYA S.
- Date : 2009
- Langues : Anglais
- Source : Int. J. Energy Res. - vol. 33 - n. 14
Voir la fiche
-
Sensitivity and design of a transcritical CO2 c...
- Auteurs : NGUYEN C., VEJE C., WILLATZEN M., et al.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Sensibilidad y diseño de un sistema de refriger...
- Auteurs : NGUYEN C., VEJE C., WILLATZEN M., et al.
- Date : 06/2013
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 41 - n. 459
- Formats : PDF
Voir la fiche
-
Approaching optimum COP by refrigerant charge m...
- Auteurs : HE Y. J., LIANG X. Y., CHENG J. H., SHAO L. L., ZHANG C. L.
- Date : 10/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
- Formats : PDF