Recommended by the IIR / IIR document
General framework for revising class A3 refrigerant charge limits – a discussion.
Author(s) : COLBOURNE D., SUEN K. O., LI T. X., VONSILD A.
Type of article: IJR article
Summary
Currently, industry and governmental entities are increasingly concerned with the restrictive controls on flammable refrigerant – particularly class A3 – charge limits, within safety standards. Since A3 refrigerants, such as R290 and R1270, are in many respects considered as desirable refrigerants to help resolve the global warming problem associated with other options (such as HFCs), safety standards should be formulated so that A3 refrigerant could be applied more widely than permitted today. An analysis of current standards reveals the extent to which A3 refrigerants currently can be applied. Further analysis of these and standards from other sectors help identify concepts and protective measures that can be applied to extend equipment across a range of larger cooling and heating capacities. The objective is to discuss how charge limits could be revised to enable a wider application of A3 refrigerants, with respect to safety regulations and associated implications, concepts and approaches available in published literature.
Available documents
Format PDF
Pages: 209-217
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: General framework for revising class A3 refrigerant charge limits – a discussion.
- Record ID : 30027522
- Languages: English
- Subject: Regulation, HFCs alternatives
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 117
- Publication date: 2020/09
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2020.04.024
Links
See other articles in this issue (35)
See the source
-
Düsük (A2l) ve yüksek (A3) tutusma potansiyelin...
- Author(s) : AREA, BUONI M.
- Date : 2016/04
- Languages : Turkish
View record
-
Attrezzatura per refrigeranti a bassa (A2l) ed ...
- Author(s) : AREA, BUONI M.
- Date : 2016/04
- Languages : Italian
View record
-
Equipment for refrigerants with lower (A2L) and...
- Author(s) : AREA, BUONI M.
- Date : 2016/04
- Languages : English
View record
-
Safety of appliances using hydrocarbon refriger...
- Author(s) : GTZ Proklima, COLBOURNE D.
- Date : 2008/07
- Languages : English
View record
-
Safe plant rooms for large hydrocarbon chillers.
- Author(s) : GTZ Proklima, TADROS A., MACLAINE-CROSS I., LEONARDI E.
- Date : 2008/07
- Languages : English
View record