Summary
To help reduce the warming impacts, this study evaluates the drop-in performances of R-427A, R-161 and R-290 in R-22 air source heat pump with EVI (Economized Vapor Injection). The results show that the IPLV(H) of R-161 and R-290 arises 5~8% relative to R-22 with EVI on. A reversal occurs between R-290 and the baseline with EVI on, making the IPLV(H) of R-290 superior to that of R-22 by 3.6~5.2% from worse performance with EVI off. At -20/41°C condition, the capacity and COP of R-290 increase by 38% and 19%, respectively. Considering COP and discharge temperatures, R-290 is better-performed to replace R-22 in high pressure ratio conditions. Based on LCCP (Life Cycle Climate Performance) model, 11% of the equivalent CO2 emission can be reduced by using R-161 and R-290. However, the discharge temperature of R-161 is high in the high pressure ratio condition. R-290 is the most synthetically beneficial alternative.
Available documents
Format PDF
Pages: 147-154
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental study on R-22, R-427A, R-161 and R-290 in air-source heat pump for space heating at low ambient temperatures.
- Record ID : 30025236
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 96
- Publication date: 2018/12
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2018.08.021
Links
See other articles in this issue (20)
See the source
Indexing
-
Themes:
HCFCs;
Residential heat-pumps;
HFCs;
Hydrocarbons - Keywords: R161; Comparison; Air-source system; R290; R22; Substitute; Heat pump; Performance; R427a
-
Experimental study on the performance of R290 a...
- Author(s) : LEI B., SHI H., WANG C., WU J., ZHANG L.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Energy comsumption and TEWI comparison of R410A...
- Author(s) : FELDMAN S. J., SPATZ M. W.
- Date : 1995/10/23
- Languages : English
- Source: Stratospheric Ozone Protection for the 90's. 1995 International CFC and Halon Alternatives Conference & Exhibition. Conference proceedings.
View record
-
Performance of Care-50 as an R22 replacement in...
- Author(s) : FIRTH A., CARRINGTON G.
- Date : 1999/09/19
- Languages : English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record
-
Operation characteristics and the method of hea...
- Author(s) : GAO Z., LI H.
- Date : 2014/08/02
- Languages : English
- Source: 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
View record
-
Comparison of R407C and R410A with R22 in a 10....
- Author(s) : LINTON J. W., SNELSON W. K., HEARTY P. F., TRIEBE A. R., MURPHY F. T., LOW R. E., GILBERT B. E.
- Date : 1996/07/23
- Languages : English
- Source: Proceedings of the 1996 Purdue International Refrigeration Conference.
View record