Experimental analysis of a new refrigerant mixture as drop-in replacement for CFC-12 and HFC-134a.
Author(s) : MANI K., SELLADURAI V.
Type of article: Article
Summary
An experimental performance study on a vapour compression refrigeration system with the new R290/R600a refrigerant mixture as drop-in replacement was conducted and compared with CFC-12 and HFC-134a. The vapour compression refrigeration system was initially designed to operate with R12. Experimental results showed that the refrigerant R290/R600a had 19.9 to 50.1% higher refrigerating capacity than R12 and 28.6 to 87.2% than R134a. The refrigerant R134a showed slightly lower refrigerating capacity than R12. The mixture R290/R600a consumed 6.8% to 17.4% more energy than R12. The refrigerant R12 consumed slightly more energy than R-134a at higher evaporating temperatures. The coefficient performance of R-290/R-600a mixture increases from 3.9 to 25.1% than R-12 at lower evaporating temperatures and 11.8 to 17.6% at higher evaporating temperatures. The refrigerant R134a showed slightly lower coefficient of performance than R12. The discharge temperature and discharge pressure of the R290/R600a mixture was very close to R12. The R-290/R-600a (68/32 by wt%) mixture can be considered as a drop-in replacement refrigerant for CFC-12 and HFC-134a. The refrigeration efficiency of the system were also studied. [Reprinted with permission from Elsevier. Copyright, 2007].
Details
- Original title: Experimental analysis of a new refrigerant mixture as drop-in replacement for CFC-12 and HFC-134a.
- Record ID : 2009-1025
- Languages: English
- Source: International Journal of thermal Sciences - vol. 47 - n. 11
- Publication date: 2008/11
Links
See other articles in this issue (1)
See the source
Indexing
-
Themes:
CFCs;
HFCs;
Hydrocarbons;
Blends - Keywords: Refrigerating system; R134a; Isobutane; R12; Substitute; Propane; Performance; Mixture; Expérimentation; COP; Refrigerant
-
Improved energy efficiency for CFC domestic ref...
- Author(s) : SEKHAR S. J., MOHAN LAL D., RENGANARAYANAN S.
- Date : 2004/03
- Languages : English
- Source: International Journal of thermal Sciences - vol. 43 - n. 3
View record
-
On the performance of HFC-134a/HC-600a/HC-290 m...
- Author(s) : SEKHAR J., PREMNATH R., LAL M.
- Date : 2003/05
- Languages : English
- Source: EcoLibrium - vol. 2 - n. 4
View record
-
Experimental evaluation of refrigerant mixtures...
- Author(s) : CAMPORESE R., BIGOLARO G., BOBBO S., CORTELLA G.
- Date : 1997/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 20 - n. 1
- Formats : PDF
View record
-
Rhône Poulenc se démarque avec la série 9.
- Author(s) : RAVEAU J. C.
- Date : 1997/04
- Languages : French
- Source: La revue pratique du froid et du conditionnement d'air - n. 845
View record
-
Experimental and theoretical investigation of t...
- Author(s) : HAINBACH C., STEIMLE F.
- Date : 1994/05/10
- Languages : English
- Source: New Applications of Natural Working Fluids in Refrigeration and Air Conditioning
- Formats : PDF
View record