Évaluation des performances par simulation de meubles frigorifiques de vente (MFV) utilisant un frigorigène HFO.
Performance evaluation by simulation of refrigerated display cabinets using HFO refrigerant.
Numéro : No 250
Auteurs : MIYAOKA Y., SUZUKI T., BIZEN K., KITAMURA K., YAMAGUCHI S., SAITO K., WATANABE T., IWASAKI T., TAKIGUCHI K.
Résumé
For protecting the global environment, low GWP refrigerants are to be incorporated in air conditioning systems and refrigerating devices, such as refrigerated display cabinets (RDCs) commonly used in convenience stores and supermarkets. R290 (propane), as a natural refrigerant, has been receiving attention as a potential working fluid alternative but poses safety issues due to its flammable characteristic. As the demand for safe refrigeration systems with easy maintenance is increasing, this study evaluated the utilization of HFO-1234yf for RDCs, and its performance was compared to R290 and other commonly used refrigerants. Simulations were conducted based on actual ambient temperature data from a convenience store. Results showed that the COP of HFO1234yf was slightly lower than those of R290 and R134a, but higher than those of R410A, R32, and R744. The annual power consumption and the annual performance factor of HFO-1234yf were very similar to those of R290. Hence, it is expected that RDCs using HFO-1234yf will perform as efficiently as those using R290.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Gratuit
Détails
- Titre original : Performance evaluation by simulation of refrigerated display cabinets using HFO refrigerant.
- Identifiant de la fiche : 30030061
- Langues : Anglais
- Sujet : Technologie
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Date d'édition : 31/08/2021
Liens
Voir d'autres communications du même compte rendu (198)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Supermarchés, meubles de vente;
HFO et HCFO;
Hydrocarbures - Mots-clés : Simulation; Meuble de vente; R1234yf; Performance; Faible GWP; R290; Propane; Comparaison; COP; Consommation d'énergie
-
Sustainable supermarket refrigeration with HFO ...
- Auteurs : PUROHIT N., GAO K., BIRBARAH P., SETHI A., HULSE R.
- Date : 05/04/2023
- Langues : Anglais
- Source : 3rd IIR conference on HFO Refrigerants and low GWP Blends. Shanghai, China.
- Formats : PDF
Voir la fiche
-
Annual performance evaluation of a refrigerated...
- Auteurs : KITAMURA K., BIZEN K., SUZUKI T., MIYAOKA Y., JEONG J., SAITO K., WATANABE T., IWASAKI T., TAKIGUCHI K.
- Date : 06/2021
- Langues : Anglais
- Source : 2nd IIR Conference on HFO Refrigerants and Low GWP Blends
- Formats : PDF
Voir la fiche
-
Thermo-economic and environmental analysis of a...
- Auteurs : HENRIQUE DE PAULA C., MOREIRA DUARTE W., MARTINS ROCHA T. T., DE PAOLI MENDES R., TORRES MAIA A. A., NUNES DE OLIVEIRA R.
- Date : 10/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
- Formats : PDF
Voir la fiche
-
A2L and A3 refrigerant testing for commercial r...
- Auteurs : WANG X.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
CO2 or R290 for Supermarket Applications – Pros...
- Auteurs : RINNE F., PAATZSCH R.
- Date : 11/04/2019
- Langues : Anglais
- Source : 8th Conference on Ammonia and CO2 Refrigeration Technology. Proceedings: Ohrid, North Macedonia, Avril 11-13, 2019.
- Formats : PDF
Voir la fiche