Etude expérimentale sur un mélange zéotropique de frigorigènes HFC-407C pour remplacer le HCFC-22 dans les systèmes de refroidisseurs de liquide.
Experimental study of zeotropic refrigerant mixture HFC-407C as a replacement for HCFC-22 in chiller systems.
Auteurs : TOLOUEE C. M., MORSI Y. S., YANG W.
Type d'article : Article
Résumé
HCFC-22 is the world's most widely used refrigerant. It serves in both residential and commercial applications, from small window units to large water chillers, and everything in between. Its particular combination of efficiency, capacity and pressure has made it a popular choice for equipment designers. Nevertheless, it does have some ozone depletion potential, so international law set forth in the Montreal Protocol and its Copenhagen and Vienna amendments have put HCFC-22 on a phase-out schedule. The zeotropic blend HFC-407C has been established as a drop-in alternative for HCFC-22 in the industry. However, when a system is charged with a zeotropic mixture, it raises concerns about temperature glide at two-phase state, differential oil solubility and internal composition shift as well as dilemma associated with the correct charge of the partially leaked systems. The purpose of this study is to investigate behaviour of R-407C in the liquid chiller systems, including performance and efficiency variations as well as challenges involved maintaining the system charged with R407C.
Détails
- Titre original : Experimental study of zeotropic refrigerant mixture HFC-407C as a replacement for HCFC-22 in chiller systems.
- Identifiant de la fiche : 2008-0514
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : EcoLibrium - vol. 5 - n. 4
- Date d'édition : 05/2006
Liens
Voir la source
Indexation
-
Thèmes :
HCFC;
Compresseurs;
HFC;
Mélanges;
Confinement, réduction de la charge en frigorigène - Mots-clés : R407C; R22; Substitut; Mélange zéotropique; HFC; Experimentation; Fuite; Frigorigène; Compresseur
-
New refrigerant fluids.
- Auteurs : MORLEY J.
- Date : 11/2003
- Langues : Anglais
- Source : RACA Journal - vol. 19 - n. 9
Voir la fiche
-
Zeotropic refrigerants in the real world: perfo...
- Auteurs : BRESNAHAN J. D., LOW R. E.
- Date : 01/05/1995
- Langues : Anglais
- Source : 1995 AIRAH Conference Proceedings.
Voir la fiche
-
Variation de concentration des mélanges de frig...
- Auteurs : KRUSE H., CHEN J.
- Date : 11/1996
- Langues : Allemand
- Source : KI Luft Kältetech. - n. 11
Voir la fiche
-
How to come to grips with the new CFC regulatio...
- Auteurs : BORER R. D.
- Date : 09/02/1993
- Langues : Anglais
- Source : CIES Environ. Module 1, Brussels - 19 p.
Voir la fiche
-
Analyse théorique des caractéristiques de fuite...
- Auteurs : XUAN Y., CHEN G.
- Date : 08/2011
- Langues : Chinois
- Source : Journal of Refrigeration - n. 140
- Formats : PDF