Document IIF
Etude expérimentale de l'effet de la longueur de ma chambre de mélange sur la performance d'un éjecteur diphasique pour un cycle frigorifique au CO2 avec et sans échangeurs de chaleur.
Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchangers.
Auteurs : NAKAGAWA M., MARASIGAN A. R., MATSUKAWA T., et al.
Résumé
In ejector systems using the promising natural refrigerant CO2, the mixing of high speed two-phase primary flow and suction vapour is crucial in designing an efficient ejector. In this study, the effect of mixing length on ejector system performance was analyzed experimentally. The mixing lengths used were 5, 15 and 25 mm, with constant rectangular cross-section. The experiments were performed for both ejector and conventional expansion systems with and without internal heat exchanger. The gas cooler pressure (9-10.5 MPa), evaporator temperature (2-8°C), and gas cooler outlet temperature (41-44°C) were varied for each type. The results showed the significant effect of mixing length in ejector's performance. The 15 mm-type provided the highest pressure recovery, entrainment ratio and COP in all the conditions used in this research. A maximum COP improvement of up to 26% compared to similar conventional system was obtained.
Documents disponibles
Format PDF
Pages : 2010-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchangers.
- Identifiant de la fiche : 2010-1149
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Date d'édition : 12/04/2010
Liens
- Voir les traductions : Investigación experimental sobre el efecto de la longitud de mezcla en el rendimiento del eyector bifásico para el ciclo de refrigeración del CO2, con y sin intercambiador de calor.
Voir d'autres communications du même compte rendu (84)
Voir le compte rendu de la conférence
-
Investigación experimental sobre el efecto de l...
- Auteurs : NAKAGAWA M., MARASIGAN A. R., MATSUKAWA T., et al.
- Date : 11/2011
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 39 - n. 441
- Formats : PDF
Voir la fiche
-
Experimental investigation of different ejector...
- Auteurs : HAFNER A., LADAM Y., ANDRESEN T., et al.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche
-
Investigación en laboratorio de diferentes geom...
- Auteurs : HAFNER A., LADAM Y., ANDRESEN T., et al.
- Date : 09/2011
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 39 - n. 439
- Formats : PDF
Voir la fiche
-
Analysis of a two-phase flow ejector for the tr...
- Auteurs : LIU F., GROLL E. A.
- Date : 14/07/2008
- Langues : Anglais
- Source : 2008 Purdue Conferences. 19th International Compressor Engineering Conference at Purdue & 12th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Experimentelle und theoretische Untersuchung ei...
- Auteurs : TISCHENDORF C., RICHTER C., FIORENZANO R., et al.
- Date : 22/11/2007
- Langues : Allemand
- Source : DKV-Tagungsbericht 2007, Hannover.
Voir la fiche