Etude expérimentale de l'effet de divers paramètres sur les taux d'infiltration des meubles frigorifiques de vente ouverts sans écoulement au niveau du panneau arrière.
Experimental investigation of the effect of various parameters on the infiltration rates of single band open vertical refrigerated display cases with zero back panel flow.
Auteurs : AMIN M., DABIRI D., NAVAZ H. K.
Résumé
Open refrigerated vertical display cases greatly contribute to the energy consumption of supermarkets. In the recent decades air curtains have significantly improved the efficiency of the systems; nevertheless, it is possible to change the design specifications of display cases to achieve higher degrees of efficiency. A simulator apparatus was constructed to easily vary several geometrical and fluid dynamic variables that affect the air curtain performances, and then a series of experimental tests were performed by a noble tracer gas technique to measure the infiltration rate in each test case scenario. The study focuses only on the cases that do not benefit from back panel flow and therefore the ratio is 1. In addition to the infiltration rate measurement, a new method using tracer gas is used to measure the total flow rate of the display case. It was found that the infiltration rate is strongly dependent on the investigated variables.
Détails
- Titre original : Experimental investigation of the effect of various parameters on the infiltration rates of single band open vertical refrigerated display cases with zero back panel flow.
- Identifiant de la fiche : 2010-0129
- Langues : Anglais
- Source : 2009 ASHRAE Annual Conference CD. Transactions papers presented at the 2009 ASHRAE Annual Conference: Louisville, KY, June 2009. Volume 115, part 2.
- Date d'édition : 21/06/2009
Liens
- Liens externes :
Voir d'autres communications du même compte rendu (30)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Supermarchés, meubles de vente
- Mots-clés : Meuble ouvert; Meuble de vente; Rideau d'air; Réduction; Supermarché; Perte thermique; Experimentation; Essai
-
Improvement of air distribution in refrigerated...
- Auteurs : GRAY I., LUSCOMBE P., MCLEAN L., et al.
- Date : 08/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 5
- Formats : PDF
Voir la fiche
-
Experimental quantitative evaluation of thermal...
- Auteurs : NASCIMENTO S. M., HEIDINGER G. G., GASPAR P. D.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
Experimental evaluation and qualitative increas...
- Auteurs : NASCIMENTO S. M., HEIDINGER G. G., GASPAR P. D.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
Refrigerated cases round-up.
- Date : 02/2004
- Langues : Anglais
- Source : S. afr. Inst. Refrig. Air Cond. - vol. 106 - n. 1271
Voir la fiche
-
Air curtain design in a vertical open display c...
- Auteurs : CORTELLA G., D'AGARO P.
- Date : 22/07/2002
- Langues : Anglais
- Formats : PDF
Voir la fiche