Summary
R290 is a potential drop-in refrigerant for existing R22 systems because of zero Ozone Depression Potential (ODP) and virtually zero Global Warming Potential (GWP). However, using R290 may result in the risk of firing. Promoting the use of smaller diameter tubes in R290 room air conditioners is an effective way to reduce refrigerant charge to avoid the risk of firing, but may cause reduction of air conditioner performance, so a design method is needed to develop low charge air conditioner by using smaller diameter tube. In this study, a simulation-based design method was developed, in which a three-dimensional distributed parameter model was used for simulation, and a knowledge-based evolution method optimizer was applied to optimize air conditioner heat exchanger with smaller diameter tube. A room air conditioner using R290 and 5 mm diameter tubes has been developed and tested. It shows that the refrigerant charge can be obviously decreased in this air conditioner comparing to those with 7 mm or 9.52 mm diameter tubes. The cooling capacity has been enhanced by optimization of heat exchanger as well as the matching of the entire system. The experimental results confirmed the simulation results, and it is also shown that 5 mm diameter tubes are suitable for developing safe room air conditioners with R290.
Available documents
Format PDF
Pages: 9 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Developing low charge R290 room air conditioner by using smaller diameter copper tubes.
- Record ID : 30004324
- Languages: English
- Source: 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Publication date: 2012/06/25
Links
See other articles from the proceedings (142)
See the conference proceedings
-
Investigation of application of suction line he...
- Author(s) : REN T., WU G., DING G., et al.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Optimization of MicroGroove Copper Tube Coil De...
- Author(s) : COTTON N. D., RHOADS A., BORTOLETTO A., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Experimental study of a novel microchannel heat...
- Author(s) : XU B., WANG Y., CHEN J. P., et al.
- Date : 2013/06/17
- Languages : English
- Source: 4th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
View record
-
Optimization of R290 heat exchangers utilizing ...
- Author(s) : TANCABEL J., AUTE V., LING J.
- Date : 2020/12/07
- Languages : English
- Source: 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
View record
-
Charge minimization in a 30kW air to water heat...
- Author(s) : PALM B.
- Date : 2014/08/02
- Languages : English
- Source: 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
View record