Document IIF
Concept frigorifique pour les petits supermarchés employant des systèmes modulaires en cascade au dioxyde de carbone et au propylène.
Refrigerating concept for small supermarkets using multiple modular cascade systems with carbon dioxide and propylene.
Auteurs : HEERUP C.
Résumé
The concept addresses the safety issues involved with hydrocarbons by minimizing the refrigerant charge and containing the hydrocarbon filled parts in a module comprising a closed cabinet. The refrigeration capacity can be satisfied by installing from 3 to 10 modules in parallel. If one module fails, the remaining will in most cases suffice as back up capacity until replacement. The modules contain each a refrigerant charge of maximum one kilogram propylene serving as the upper stage of a cascade system. The condensers for the upper stages are cooled by a conventional dry cooler circuit. The upper stage is cooling the primary side of a plate heat exchanger, the secondary side acting as condenser for carbon dioxide as the secondary refrigerant. The liquid carbon dioxide is pumped to the low temperature display cabinets via expansion valves and is returned to the condenser by multiple rolling piston compressors, thus completing the low stage of the cascade system. The medium temperature display cabinets are simply pump fed via solenoid valves with liquid carbon dioxide which partly or totally evaporates and then returns to the condenser.
Documents disponibles
Format PDF
Pages : 2004-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Refrigerating concept for small supermarkets using multiple modular cascade systems with carbon dioxide and propylene.
- Identifiant de la fiche : 2005-1900
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Date d'édition : 01/08/2004
Liens
Voir d'autres communications du même compte rendu (105)
Voir le compte rendu de la conférence
Indexation
-
Alternative refrigerants for supermarket systems.
- Auteurs : HAAF S.
- Date : 15/10/2002
- Langues : Anglais
- Source : Symposium 2002. Environment, efficiency, economics: optimal refrigerant selection for refrigeration and air-conditioning systems under special consideration of emission reduction, safety risks, energy efficiency, economical aspects and service.
Voir la fiche
-
Natural refrigerants in supermarket refrigeration.
- Auteurs : ELEFSEN F.
- Date : 02/05/2001
- Langues : Anglais
- Source : AIRAH 2001 National Conference Proceedings.
Voir la fiche
-
Kälteanlagen für Supermärkte mit alternativen K...
- Auteurs : HAAF S., HEINBOKEL B.
- Date : 11/2003
- Langues : Allemand
- Source : KI Luft Kältetech. - vol. 39 - n. 11
Voir la fiche
-
Opportunities for CO2 in supermarket refrigerat...
- Auteurs : VERHOEF P. J.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Carbon dioxide for supermarkets.
- Auteurs : CAMPBELL A., MISSENDEN J. F., MAIDMENT G. G.
- Date : 2006
- Langues : Anglais
- Source : Annual proceedings of the Institute of Refrigeration. 2006-2007 [CD-ROM].
Voir la fiche