Comparaison entre les meubles frigorifiques anciens et récents.
Comparing older and newer refrigerated display cases.
Auteurs : FARAMARZI R., KEMP K.
Type d'article : Article
Résumé
Medium temperature display cases consume roughly 18% of the total electricity used by a supermarket. Open multideck meat/dairy/deli cases can contribute up to 25% of the refrigeration energy consumption. The Food and Drug Administration (FDA) classifies fresh meat, deli and dairy products as hazardous foods and require them to be stored at less than 5 °C at all times. In the absence of unbiased performance test data, the equipment purchasing staff for supermarkets frequently rely on the manufacturers' literature with respect to the performance and energy efficiency of refrigerated merchandisers. The manufacturer's literature provides the conventional cooling capacity and evaporator temperature of the case.
Détails
- Titre original : Comparing older and newer refrigerated display cases.
- Identifiant de la fiche : 2001-0199
- Langues : Anglais
- Source : ASHRAE Journal - vol. 41 - n. 8
- Date d'édition : 08/1999
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
- Voir les traductions : Comparación entre vitrinas de exposicíon refrigeradas viejas y nuevas.
Voir d'autres articles du même numéro (3)
Voir la source
Indexation
- Thèmes : Supermarchés, meubles de vente
- Mots-clés : Comparaison; Meuble de vente; Conception; Rideau d'air; Supermarché; Performance; Optimisation; Éclairage
-
Comparación entre vitrinas de exposicíon refrig...
- Auteurs : FARAMARZI R., KEMP K.
- Date : 09/2001
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 29 - n. 329
Voir la fiche
-
Promotion of energy efficient display cabinets.
- Auteurs : AXELL M., FAHLÉN P. O.
- Date : 1999
- Langues : Anglais
- Source : Refrigerated Transport, Storage and Retail Display.
- Formats : PDF
Voir la fiche
-
Experimental evaluation and qualitative increas...
- Auteurs : NASCIMENTO S. M., HEIDINGER G. G., GASPAR P. D.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
Application of an effective strategy for optimi...
- Auteurs : CAO Z., GU B., HAN H., et al.
- Date : 06/2010
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 49 - n. 6
Voir la fiche
-
Experimental quantitative evaluation of thermal...
- Auteurs : NASCIMENTO S. M., HEIDINGER G. G., GASPAR P. D.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche