Document IIF
Analyse de simulation des systèmes à débit de frigorigène variable avec plusieurs unités intérieures.
Simulation analysis of Variable Refrigerant Flow Systems with multi indoor units.
Numéro : 0121
Auteurs : MATSUMOTO K., SAITO K., YAMAGUCHI S.
Résumé
To realize a carbon-neutral society, it is essential to focus on technological advancements in both energy supply and demand sectors. From the perspective of energy demand, there are various approaches for achieving a carbon-neutral society, such as, promoting energy-saving technology and levelling the load curve to maximize the use of effective supply resources. Thus, innovation contributes to a carbon-neutral society. Particularly, in commercial buildings, it is important to promote the use of electric air conditioners throughout the year to replace fossil fuel energy sources. The installation of variable refrigerant flow (VRF) systems plays an important role in achieving a carbon-neutral society. Single indoor unit systems are almost similar to the optimum control method; however, some multi-indoor unit VRF systems operate under lower COP (Coefficient Of Performance) conditions. The goal of this study is identify the factors contributing to lower COP conditions and identify areas for improvement through simulation analysis. Furthermore, we propose a new control method for the multi-indoor units of VRF systems that simultaneously achieves both energy saving and increased stability.
Documents disponibles
Format PDF
Pages : 12
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Simulation analysis of Variable Refrigerant Flow Systems with multi indoor units.
- Identifiant de la fiche : 30031490
- Langues : Anglais
- Sujet : Technologie
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0121
Liens
Voir d'autres communications du même compte rendu (373)
Voir le compte rendu de la conférence
-
A heat recovery unit with adjustable heat excha...
- Auteurs : LIANG C., WANG H., FANG L., NAKAZAWA T., TANAKA T., LI X.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Numerical investigation on effects of sub-coole...
- Auteurs : OH B., KIM D., JEONG H., PARK Y., CHOI J., MIN B., CHOI G.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Field measurement on rooftop condensing unit be...
- Auteurs : TOMLEIN P.
- Date : 13/01/2021
- Langues : Anglais
- Source : 10th IIR Conference on Compressors and Refrigerants.
- Formats : PDF
Voir la fiche
-
Study on the smart operation approach of an air...
- Auteurs : YOON M. S., YOON W. S.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche
-
A novel performance model based on capacity uti...
- Auteurs : XIAO H., LIU S., DING Y., ZHENG C. Y., NIU H., WANG B., YANG Z., SHI W.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche