Document IIF
Amélioration de la distribution d'air régulée dans les meubles frigorifiques de vente verticaux et ouverts de supermarché.
Improvement of air distribution in refrigerated vertical open front remote supermarket display cases.
Auteurs : GRAY I., LUSCOMBE P., MCLEAN L., et al.
Type d'article : Article, Article de la RIF
Résumé
This paper presents some of the results derived from extensive experimentation on display cases for supermarkets and derives some possible improvements to augment temperature uniformity and energy performance. The effect of the perforation pattern of the rear duct on the distribution of airflow between these and the front curtain is brought out. The critical component is air infiltration across the curtain, which is governed by internal air distribution and curtain characteristics. It is observed that a 70-30 distribution of flow between the curtain and the rear duct perforations yields a performance that satisfies the standards. Further, a judicious distribution of perforations on the rear duct at various levels and across is necessary. Correlations available in the literature are useful in making a qualitative assessment of the results.
Documents disponibles
Format PDF
Pages : 902-910
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Improvement of air distribution in refrigerated vertical open front remote supermarket display cases.
- Identifiant de la fiche : 2008-1652
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 5
- Date d'édition : 08/2008
Liens
Voir d'autres articles du même numéro (19)
Voir la source
Indexation
- Thèmes : Supermarchés, meubles de vente
- Mots-clés : Meuble ouvert; Meuble de vente; Rideau d'air; R507; Supermarché; Experimentation; Distribution d'air
-
Experimental investigation of the effect of var...
- Auteurs : AMIN M., DABIRI D., NAVAZ H. K.
- Date : 21/06/2009
- Langues : Anglais
- Source : 2009 ASHRAE Annual Conference CD. Transactions papers presented at the 2009 ASHRAE Annual Conference: Louisville, KY, June 2009. Volume 115, part 2.
Voir la fiche
-
Experimental evaluation and qualitative increas...
- Auteurs : NASCIMENTO S. M., HEIDINGER G. G., GASPAR P. D.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
Experimental quantitative evaluation of thermal...
- Auteurs : NASCIMENTO S. M., HEIDINGER G. G., GASPAR P. D.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
Analyse et numérisation d'images d'écoulements ...
- Auteurs : PENOT F., MORILLON C., MOUSSET S.
- Date : 20/08/1995
- Langues : Français
- Source : For a Better Quality of Life. 19th International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Air curtain design in a vertical open display c...
- Auteurs : CORTELLA G., D'AGARO P.
- Date : 22/07/2002
- Langues : Anglais
- Formats : PDF
Voir la fiche