Recommended by the IIR / IIR document
A3 refrigerant R290 leak and ignition testing for refrigerated display cases.
Number: 292779
Author(s) : WANG X.
Summary
R290 (propane) is a flammable refrigerant having an A3 classification according to the ASHRAE Standard 34. Because of its extremely low Global Warming Potential (GWP), several regions around the world use or consider using it for refrigeration applications. On the other hand, the R290 application was limited to small charged self-contained products in most of the world due to its high flammability and safety implications.
The Air-Conditioning, Heating, and Refrigeration Technology Institute (AHRTI) conducted the R290 leak and ignition testing under whole room scale conditions. This paper summarizes the test results for a single door and a three-door refrigerated display cases in a full-scale room. The testing simulated refrigerant leaks from the display cases with ignition sources present. R290 charge levels ranging from 114g to 400g were tested. The tests also included using the condenser fan circulation to disperse leaked refrigerant as a mitigation method.
Available documents
Paper
Pages: 6
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
PowerPoint version
Pages: 15
Available
Public price
5 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Video
Available
Public price
10 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: A3 refrigerant R290 leak and ignition testing for refrigerated display cases.
- Record ID : 30027588
- Languages: English
- Subject: HFCs alternatives
- Source: 6th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Nantes, France, August 26-28 2020
- Publication date: 2020/08/26
- DOI: http://dx.doi.org/10.18462/iir.iccc.2020.292779
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (84)
See the conference proceedings
Indexing
-
Concentrations of hydrocarbon refrigerant exiti...
- Author(s) : COLBOURNE D., SUEN K. O.
- Date : 2022/06/13
- Languages : English
- Source: 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
View record
-
Ignition sources at the stage of usage for mini...
- Author(s) : TAMURA K., TAKAICHI K., TAIRA S., BABA A., ITAKURA S., MORI H., MAKINO H.
- Date : 2020/12/07
- Languages : English
- Source: 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
View record
-
Quantitative risk assessment of R290 in ice cre...
- Author(s) : COLBOURNE D., ESPERSEN L.
- Date : 2013/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 4
- Formats : PDF
View record
-
A3 Refrigerant R290 leak and ignition testing i...
- Author(s) : WANG X.
- Date : 2020/12/07
- Languages : English
- Source: 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
View record
-
Risk assessment of built-in refrigerated displa...
- Author(s) : YAMASHITA K., SAKAMOTO Y., KATO T., ISHIHARA S., KOBAYASHI A., KAINUMA H., HASEGAWA T., NAGAI H., HOSAKA K.
- Date : 2021/08/31
- Languages : English
- Source: 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
View record